+86-15335445857

Precautions for Using Mobile Asphalt Tanks: Tips for Transportation Fixing, On-Site Piping Layout & Temporary Power Adaptation

Release Date:

Precautions for Using Mobile Asphalt Tanks: Tips for Transportation Fixing, On-Site Piping Layout Temporary Power Adaptation Mobile asphalt tanks are critical equipment for road construction, emergency maintenance, and remote project sites—their mobility

Precautions for Using Mobile Asphalt Tanks: Tips for Transportation Fixing, On-Site Piping Layout & Temporary Power Adaptation

Mobile asphalt tanks are critical equipment for road construction, emergency maintenance, and remote project sites—their mobility allows flexible asphalt storage and heating, but improper use during transportation, on-site installation, or power connection can lead to safety hazards (e.g., tank tipping, asphalt leakage, electrical short circuits) or equipment damage (average repair cost exceeds $5,000). Unlike fixed asphalt tanks, mobile models require more attention to "dynamic stability" (during transportation) and "temporary adaptability" (on-site setup). This article focuses on three core links—transportation fixing, on-site piping layout, and temporary power adaptation—to detail operational precautions, risk points, and practical tips, ensuring safe and efficient use.

1. Transportation Fixing: Ensure "No Shifting, No Vibration" to Prevent Tank Tipping & Asphalt Leakage

Transportation is the highest-risk stage for mobile asphalt tanks—unsecured tanks may shift or tip due to road bumps (especially on rural dirt roads or construction site access roads), and asphalt leakage (caused by loose valves) can damage roads or cause fires. Transportation fixing requires a "two-step check" (before departure and during transit) and strict adherence to load limits.

1.1 Pre-Departure Fixing: Lock Tanks, Seal Valves, and Check Load Distribution

Tank Body Fixing: Use high-strength steel chains (breaking strength ≥ 5 tons) and turnbuckles to secure the tank to the transport vehicle’s chassis. Fasten 4-6 anchor points (evenly distributed around the tank base) — each chain should be tightened until there is no slack (use a torque wrench to ensure tension is 80-100 N·m; over-tightening may deform the tank base, while under-tightening causes shifting). For tanks with a capacity of 50m³ or more, add auxiliary support blocks (made of hardwood or rubber, thickness ≥ 10cm) between the tank and chassis to reduce vibration during transit.

Valve and Pipe Sealing: Close all asphalt outlet valves (manual valves should be turned 2-3 full turns after closing to ensure tightness) and use thread seal tape (PTFE tape) to wrap the valve connections—this prevents asphalt from leaking through thread gaps. For the heating oil pipes (if the tank uses oil-fired heating), install a shut-off valve at the pipe inlet and close it to avoid heating oil leakage.

Load Distribution Check: Ensure the tank’s center of gravity aligns with the transport vehicle’s axle center. For partially filled tanks (e.g., 30% of total capacity), add anti-slosh baffles inside the tank (if not pre-installed) to reduce asphalt sloshing—uncontrolled sloshing can cause the vehicle to sway, increasing the risk of tipping. Use a level to confirm the tank is horizontal (tilt angle ≤ 2°) before departure; uneven loading will strain the fixing chains.

1.2 In-Transit Monitoring: Avoid High Speeds and Frequent Braking

Speed Control: Travel at a speed of 40-60 km/h on highways and ≤ 30 km/h on construction site roads. High speeds (over 70 km/h) will amplify road vibrations, loosening the fixing chains or damaging the tank’s internal heating tubes. Avoid sudden acceleration or braking—this can cause asphalt to surge, pushing the tank forward or backward and breaking the anchor points.

Regular Checks: Stop every 50 km to inspect the fixing chains (re-tighten if slack is found) and valve seals (wipe the valve surface with a clean cloth; if asphalt stains appear, re-wrap the threads with seal tape). For long-distance transportation (over 200 km), check the tank’s pressure relief valve (a key safety component) to ensure it is not blocked—blockage can cause pressure buildup inside the tank, leading to dangerous overpressure.

2. On-Site Piping Layout: Ensure "Smooth Flow, No Leakage" to Avoid Asphalt Solidification & Equipment Damage

On-site piping connects the mobile asphalt tank to asphalt spreaders, mixers, or heating systems. Improper layout (e.g., steep pipe slopes, loose connections) can cause asphalt solidification (in cold weather) or leakage, halting construction progress. Piping layout must follow "flow logic" and "environmental adaptation" principles.

2.1 Piping Material and Slope: Match Asphalt Temperature and Ensure Unobstructed Flow

Material Selection: Use seamless carbon steel pipes (DN50-DN100, wall thickness ≥ 5mm) for asphalt transport—PVC or plastic pipes cannot withstand high asphalt temperatures (120-180°C) and will melt. For the heating circuit (if using hot oil circulation), use heat-resistant steel pipes (e.g., 316 stainless steel) to avoid pipe bursting due to high-temperature oil (200-250°C).

Slope Design: The asphalt pipe should have a downward slope of 3‰-5‰ (i.e., a 3-5cm drop per 10 meters) to ensure asphalt flows by gravity—avoid horizontal or upward slopes, which will cause asphalt to accumulate and solidify (especially in temperatures below 10°C). If the site terrain requires an upward section, install a booster pump (pressure ≥ 0.3 MPa) to push asphalt through, and insulate the upward pipe section (with 50mm-thick rock wool insulation) to maintain temperature.

2.2 Connection and Insulation: Prevent Leakage and Heat Loss

Sealed Connections: Use flange connections (with heat-resistant gaskets, e.g., graphite gaskets) for pipe joints—threaded connections are prone to leakage at high temperatures. Tighten flange bolts with a torque wrench (torque 120-150 N·m for DN50 pipes) and apply high-temperature sealant (temperature resistance ≥ 200°C) around the gasket to enhance sealing. After connection, conduct a pressure test: inject compressed air (0.2 MPa) into the pipe and apply soapy water to joints—no bubbles indicate a tight seal.

Insulation and Heating: Insulate all asphalt pipes with rock wool or ceramic fiber insulation (thickness 50-80mm) and wrap them with aluminum foil to prevent heat loss. In cold weather (below 0°C), install electric heat tracing cables (power 20-30 W/m) along the pipes—set the tracing temperature to 130-150°C to keep asphalt in a fluid state. Avoid placing pipes near open flames (e.g., construction site stoves) or sharp objects (e.g., excavator buckets), which can damage insulation or puncture pipes.

2.3 On-Site Layout Safety: Avoid Obstacles and Ensure Emergency Access

Path Planning: Lay pipes along the edge of the construction site, away from pedestrian walkways, vehicle paths, and excavation areas. Maintain a 1-meter clearance between pipes and heavy equipment (e.g., loaders, rollers) to prevent accidental collision. If pipes must cross a road, install a protective steel cover (thickness ≥ 10mm) over the pipe to withstand vehicle weight.

Emergency Valves: Install a shut-off valve every 10 meters along the asphalt pipe and a pressure relief valve at the highest point of the pipe—if asphalt solidifies and blocks the pipe, the pressure relief valve will release excess pressure to prevent pipe explosion. Label all valves clearly (e.g., "Asphalt Inlet Valve," "Emergency Shut-Off Valve") to ensure quick operation in case of leakage.

3. Temporary Power Adaptation: Ensure "Stable Voltage, Safe Wiring" to Prevent Electrical Faults

Mobile asphalt tanks rely on temporary power for heating systems (electric heaters), pumps, and control panels. Unstable voltage or improper wiring can damage electrical components (e.g., heating elements, control boards) or cause electric shocks. Power adaptation must focus on "voltage stability" and "safety protection."

3.1 Voltage Matching and Stabilization: Avoid Overloading Electrical Components

Voltage Check: Confirm the tank’s rated voltage (most mobile models use 380V three-phase power; small tanks may use 220V single-phase power) and match it to the on-site temporary power supply. Use a multimeter to measure the supply voltage—variations should be within ±5% of the rated voltage (e.g., 361-399V for 380V tanks). If the site has voltage fluctuations (common in remote areas), install a voltage stabilizer (capacity ≥ 1.2 times the tank’s total power; e.g., a 10kW stabilizer for an 8kW tank) to prevent damage to the heating system.

Power Load Calculation: Calculate the total power of the tank’s electrical components (heaters + pumps + control system) and ensure the temporary power cable can handle the load. For example, a tank with a 6kW heater and 2kW pump (total 8kW) requires a 4mm² three-phase copper cable (current-carrying capacity ≥ 20A); using a 2.5mm² cable will cause overheating and cable melting. Avoid sharing the same power circuit with other high-power equipment (e.g., electric welders, concrete mixers)—this will cause voltage drops and affect the tank’s heating efficiency.